Specifications Current Measurement Range: 0 to 24 mA Resolution: 0.001 mA Accuracy: 0.015% Rdg + 2 LSD Current Sourcing Range: 0 to 20 mA or 4 to 20 mA Accuracy: 0.015% Rdg + 2 LSD ....
CAN ELECTRONIC INDONESIA We are trading company established in Jakarta. Especially " Instrument Measuring Electronic Test & Tools Education / Industry / Enviroment Equipment " CAN ELECTRONIC....
Overview Features Specifications More Info The feature-packed 424D distance meters measures up to any situation. Measures up to 100 m ( 330 ft) Higher accuracy: + / -1 mm ( 0.04 in) 4-line....
Specifications Current Measurement Range: 0-1 A, Resolution: 1 mA Accuracy: 0.2% + 2 LSD Range: 0-30 mA Resolution: 0.001 mA Accuracy: 0.05% + 2 LSD Current Sourcing Range: 0-20 mA....
Specifications Current Measurement Range: 0-1 A AC or DC Resolution: 1 mA Accuracy: 0.2% + 2 LSD ( DC) Range: 0-30 mA Resolution: 0.001 mA Accuracy: 0.05% + 2 LSD Current....
Environmental Specifications Diameter of measurable conductor 0.177 or 4.5 mm max Operating temperature -10 to 50 C Storage Temperature -25 to 60 C Operating Humidity < 90% @ < 30....
Specifications Diameter of measurable conductor 0.177 or 4.5 mm max Operating temperature -10 to 50 C Storage Temperature -25 to 60 C Operating Humidity < 90% @ < 30 C, < 75% @ ....
Specifications Temperature -20 C to 60 C ( -4 F to 140 F) Temperature accuracy 0 C to 45 C ( 0.5 C) -20 C to 0 C & 45 C to 60 C ( 1.0 C) 32 F to 113 F ( 1....
Technical Specifications Voltage range 40-700 V Frequency range 15-400 Hz Operating timer Continuous Environmental Specifications Operating temperature 0 C to 40 C Dust/ water....
Insulation resistance measurement Test voltage ( dc) Range ( dc) Accuracy ( reading) 250 V 50 G unspecified 5 % 20 % unspecified 500 V 200 k 200 k to 10 G 10 G to....
Specifications Voltage DC Maximum Voltage: 1000 V Accuracy: 1577: ( 0.2% + 2) 1587: ( 0.09% + 2) Maximum Resolution: 0.001V Voltage AC Maximum Voltage: 1000 V Accuracy: 1577: ....
AC/ DC Voltage Measurement Accuracy Range 600.0 V Resolution 0.1 V 50 Hz to 400 Hz ( % of Rdg + Digits) ( 2 % + 3) Input impedance 3 M ( nominal) , 60 dB at dc, 50 or 60 Hz ....
Technical Specifications Voltage measurement range Transmitter: 12 V, 50 V, 120 V, 230 V, 400 V Frequency range Transmitter: 0...60 Hz Output signal Transmitter: 125 kHz Voltage ....
Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse ( ....
Specifications Voltage DC 175 - Accuracy* ( 0.15% + 2) 177 - Accuracy* ( 0.09% + 2) 179 - Accuracy* ( 0.09% + 2) Max. Resolution 0.1 mV Maximum 1000 V Voltage AC Accuracy* ....