Specifications Voltage DC Maximum Voltage : 1000V Accuracy: Fluke 83 V: ( 0.1% + 1) Fluke 87V: ( 0.05% + 1) Maximum Resolution: Fluke 83 V: 100 V Fluke 87 V: 10 V Voltage AC ....
CAN ELECTRONIC INDONESIA We are trading company established in Jakarta. Especially " Instrument Measuring Electronic Test & Tools Education / Industry / Enviroment Equipment " CAN ELECTRONIC....
Temperature Temperature measurement range -10 C to + 250 C ( 14 F to 482 F) Temperature measurement accuracy 2 C or 2% of reading in C, whichever is the greater ( at 25 ....
Specifications Diameter of measurable conductor 01.3 or 34 mm max Operating temperature -14 to 122 F ( -10 to 50 C) Storage Temperature -40 to 140 F ( -40 to 60 C) Operating....
Specifications Diameter of measurable conductor 0.12 or 30.5 mm max Operating temperature -14 to 122 F ( -10 to 50 C) Storage Temperature -40 to 140 F ( -40 to 60 C) Operating....
General Specifications Digital Display 6000 count resolution Low Battery Indication Displays a signal when the batteries are below their required voltage Power Source Three AAA IEC LR03....
FLUKE 1625 Kit, Advanced GEO EarthTester. Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to....
Overview Features Specifications Models and Accessories More Info The 419D distance meters offer these enhanced features: Measure up to 80 m ( 260 ft) Higher accuracy: + / -1 mm ( 0.04....
Environmental Parameters Drop Specification: 3.3 ft Max Operating Temperature: 113 F Max Storage Temperature: 140 F Min Operating Temperature: 32 F Min Storage....
Measures -40 C to 800 C/ -40 F to 1472 F Easily access advanced features with the soft-key buttons and graphical display Measure smaller objects from further away, with a distance-to....
Specifications Current Measurement Range: 0 to 24 mA Resolution: 0.001 mA Accuracy: 0.02% Rdg + 2 LSD Current Sourcing Range: 0 to 20 mA or 4 to 20 mA Accuracy: 0.025% Rdg + 2 LSD ....
Features at a Glance: Measure loop current ( 0-20 mA, 4-20 mA) signals with very high accuracy of 0.015% and 1 mA resolution Measure voltage output process signals from PLCs, transmitters Source....
Measurement Accuracy Voltage DC 30.000 V 0.02% + 2 counts ( upper display) 20.000 V 0.02% + 2 counts ( lower display) 100.00 mV 0.02% + 2 counts -10.00 mV to 75.00 mV 0.025 % + 1....
Measurement Accuracy Voltage DC 30.000 V 0.02% + 2 counts ( upper display) 30.000 V 0.02% + 2 counts ( lower display) 100.00 mV 0.02% + 2 counts -10.00 mV to 75.00 mV 0.025 % + 1 count....
Measurement Accuracy Voltage DC 30.000 V 0.01% + 2 mV ( upper display) 20.000 V 0.01% + 2 mV ( lower display) 90.00 mV 0.01% + 10 V -10.00 mV to 75.00 mV 0.025 % + 1 count ( via TC....